Fire at will…

for our safety cable Logicable Safety BD with E30 – E90 functional preservation. This cable has become an installation standard in public buildings and industrial facilities to transmit audio, control and test signals. Due to the use of a special polymer it complies with the fire protection requirements according to DIN VDE 4102 part 12, E30 – E90 and FE180 (DIN VDE 0472, part 814). Please note that cables of this type are not suitable for mobile applications. Functional preservation depends on the installation technique.
Non-flammability in compliance with DIN VDE 0482 part 266-2, EN 50266-2 and IEC 60332-3. Freedom of halogens and gases (no corrosive gases) in compliance with DIN VDE 0482 parts 267-2 EN50267-2 and IEC 60754-2. Low smoke density in compliance with DIN VDE 0482 parts 268, EN 50268 and IEC 61034. Flame resistant in connection with water at 650 °C: 15 minutes (BS8367; W).

Not suitable for the use of power current and for underground installation.

Advantages:

  • Available in 2- to 12-wire version
  • Complies with the high fire protection requirements according to DIN VDE 4102 part 12, E30 – E90, and other relevant DIN standards.
  • Perfect protection against external electrical interferences and prevention of a flame transmission

Application:

  • Transmission of measuring, control and data signals in fire prone rooms.
  • Fixed installation in building technology
Article number 100-1173
Name Logicable Safety BD
Properties Analog
Properties OFC oxygen free copper
Properties FRNC flame retardant
Properties Protection class E90
Properties Halogen-free / LSZH
Properties Protection class E30
Application area ELA 100 V
Application area Installation
Application Fire alarm cable
Colour red
Colour detailed red
Signal transmission symmetrical
Jacket material HM1 FRNC
Jacket material (audio) Flame retardant and halogen-free polymer HM1
Inner conductor (audio) 2
Inner conductor (audio) [mm²] 0,50
Inner conductor Ø (audio) [mm] 0,80
AWG (audio) 20
Shielding AL / PT foil
Shielding factor [%] 100
Conductor insulation material silicone E12
Style variant round
Packing bulk stock
Temperature min. [°C] -20
Temperature max. [°C] 90
Width [mm] 7,9
[mm] 7,9
Capac. cond./cond. per 1 m (audio) [pF] 110
Capacity wire/wire at 1 ft. (audio) [pF] 33,528
Capac. cond./shield. per 1 m (audio) [pF] 250
Capacity wire/electic screen at 1 ft. (audio) [pF] 76,2
Impedance [Ω] 105
Insulation resist. per 1 km [GΩ] 500
Insulation resist. per 1000 feet [GΩ] 152,4
Insulation resist. per 1 km (audio) [GΩ] 500
Insulation resist. per 1000 feet (audio) [GΩ] 152,4
Loop resistance per km [Ω] 75
Loop resistance per 1000 ft. [Ω] 22,86
BPVo-Euroclass Fca

Fire at will…

for our safety cable Logicable Safety BD with E30 – E90 functional preservation. This cable has become an installation standard in public buildings and industrial facilities to transmit audio, control and test signals. Due to the use of a special polymer it complies with the fire protection requirements according to DIN VDE 4102 part 12, E30 – E90 and FE180 (DIN VDE 0472, part 814). Please note that cables of this type are not suitable for mobile applications. Functional preservation depends on the installation technique.
Non-flammability in compliance with DIN VDE 0482 part 266-2, EN 50266-2 and IEC 60332-3. Freedom of halogens and gases (no corrosive gases) in compliance with DIN VDE 0482 parts 267-2 EN50267-2 and IEC 60754-2. Low smoke density in compliance with DIN VDE 0482 parts 268, EN 50268 and IEC 61034. Flame resistant in connection with water at 650 °C: 15 minutes (BS8367; W).

Not suitable for the use of power current and for underground installation.

Advantages:

  • Available in 2- to 12-wire version
  • Complies with the high fire protection requirements according to DIN VDE 4102 part 12, E30 – E90, and other relevant DIN standards.
  • Perfect protection against external electrical interferences and prevention of a flame transmission

Application:

  • Transmission of measuring, control and data signals in fire prone rooms.
  • Fixed installation in building technology
Article number 100-1173
Name Logicable Safety BD
Properties Analog
Properties OFC oxygen free copper
Properties FRNC flame retardant
Properties Protection class E90
Properties Halogen-free / LSZH
Properties Protection class E30
Application area ELA 100 V
Application area Installation
Application Fire alarm cable
Colour red
Colour detailed red
Signal transmission symmetrical
Jacket material HM1 FRNC
Jacket material (audio) Flame retardant and halogen-free polymer HM1
Inner conductor (audio) 2
Inner conductor (audio) [mm²] 0,50
Inner conductor Ø (audio) [mm] 0,80
AWG (audio) 20
Shielding AL / PT foil
Shielding factor [%] 100
Conductor insulation material silicone E12
Style variant round
Packing bulk stock
Temperature min. [°C] -20
Temperature max. [°C] 90
Width [mm] 7,9
[mm] 7,9
Capac. cond./cond. per 1 m (audio) [pF] 110
Capacity wire/wire at 1 ft. (audio) [pF] 33,528
Capac. cond./shield. per 1 m (audio) [pF] 250
Capacity wire/electic screen at 1 ft. (audio) [pF] 76,2
Impedance [Ω] 105
Insulation resist. per 1 km [GΩ] 500
Insulation resist. per 1000 feet [GΩ] 152,4
Insulation resist. per 1 km (audio) [GΩ] 500
Insulation resist. per 1000 feet (audio) [GΩ] 152,4
Loop resistance per km [Ω] 75
Loop resistance per 1000 ft. [Ω] 22,86
BPVo-Euroclass Fca