These two don’t want to know each other...
and this in one jacket! To minimize the diameter or to save space, AES/EBU or DMX cables are normally wired in crossover mode as is the case with our BINARY 434 cable. In the worst case the wires can move a little under extremely tough use, which might result in a slightly wider tolerance range of the electrical data. To be on the safe side, one can now go for the somewhat more sophisticated version, where the two wire pairs are shielded individually and once again insulated from each other by an AL/PT foil. Of course, the cable will thereby grow a little in diameter which, however, will give the cable additional stability. The new Binary 422 TP DMX512 (TWISTED PAIR) is delivered in a cold resistant and notch-proof S-PVC jacket. With its double shielding (AL/PT foil + Cu braid) and the wire coding it complies with the generally applicable regulations (VDE 0812/VDE 0207). Transfer speed 256 Kbs pursuant to EIA 485.
Advantages:
- Digital transmission over long distances due to the DMX and AES/EBU standards
- Excellent protection against electric interference (Cu mesh screen + AL/PT foil)
plus Twisted Pair design - Extremely robust due to the special tough jacket
Application:
- Networking of scanners and lighting systems with check-back function
- Connection of digital control units and devices of all kinds
- S-PVC jacket for mobile outdoor applications
Article number | 542-0051 |
---|---|
Name | Binary 422 TP DMX512 |
EAN | 4049371002424 |
Properties | Digital 110 Ω AES / EBU |
Properties | OFC oxygen free copper |
Properties | Analog |
Properties | In-ground / burial |
Application area | ELA 100 V |
Application area | Stage / live |
Application area | Installation |
Application area | Studio / Broadcast |
Application area | Mobile outdoor / indoor |
Application | DMX |
Colour | black |
Colour detailed | black |
Signal transmission | symmetrical |
Construction | [2(2LI2YS0,22mm²)(ST)]CY |
Jacket material | S-PVC |
Jacket Ø [mm] | 8,00 |
Number of Channels (AES/EBU, DMX) | 1 |
Inner conductor (AES/EBU, DMX) | 4 |
Inner conductor (AES/EBU, DMX) [mm²] | 0,22 |
Inner conductor Ø (AES/EBU, DMX) [mm] | 0,53 |
AWG (AES/EBU, DMX) | 24 |
Shielding | Copper braiding tin-plated + 2 x AL / PT foil |
Shielding factor [%] | 100 |
Copper strands (AES/EBU, DMX) | 7 |
Copper strand Ø (AES/EBU, DMX) [mm] | 0,20 |
Conductor insulation material | Foam / Skin-PE |
Conductor insulation Ø [mm] | 1,55 |
Weight per 1 m [g] | 76 |
UV-resistant | yes |
Fire load per m [kWh] | 0,25 |
Style variant | round |
Packing | 100 m spool |
Temperature min. [°C] | -25 |
Temperature max. [°C] | 70 |
Width [mm] | 8 |
[mm] | 8 |
Capac. cond./cond. per 1 m (AES/EBU, DMX) [pF] | 45 |
Capacity wire/wire at 1 ft. (AES/EBU, DMX) [pF] | 13,716 |
Capac. cond./shield. per 1 m (AES/EBU, DMX) [pF] | 110 |
Capacity wire/electic screen at 1 ft. (AES/EBU, DMX) [pF] | 33,528 |
Impedance [Ω] | 110 |
Insulation resist. per 1 km [GΩ] | 0,1 |
Insulation resist. per 1000 feet [GΩ] | 0,0305 |
Insulation resist. per 1 km (AES/EBU, DMX) [GΩ] | 0,1 |
Insulation resist. per 1000 feet (AES/EBU, DMX) [GΩ] | 0,0305 |
Conductor resistance per 1 km [Ω] | 87 |
Conductor resistance per 1000 ft. [Ω] | 26,5176 |
Shield. resistance per 1 km [Ω] | 15 |
Shield. resistance per 1000 ft. [Ω] | 4,572 |
BPVo-Euroclass | Fca |
These two don’t want to know each other...
and this in one jacket! To minimize the diameter or to save space, AES/EBU or DMX cables are normally wired in crossover mode as is the case with our BINARY 434 cable. In the worst case the wires can move a little under extremely tough use, which might result in a slightly wider tolerance range of the electrical data. To be on the safe side, one can now go for the somewhat more sophisticated version, where the two wire pairs are shielded individually and once again insulated from each other by an AL/PT foil. Of course, the cable will thereby grow a little in diameter which, however, will give the cable additional stability. The new Binary 422 TP DMX512 (TWISTED PAIR) is delivered in a cold resistant and notch-proof S-PVC jacket. With its double shielding (AL/PT foil + Cu braid) and the wire coding it complies with the generally applicable regulations (VDE 0812/VDE 0207). Transfer speed 256 Kbs pursuant to EIA 485.
Advantages:
- Digital transmission over long distances due to the DMX and AES/EBU standards
- Excellent protection against electric interference (Cu mesh screen + AL/PT foil)
plus Twisted Pair design - Extremely robust due to the special tough jacket
Application:
- Networking of scanners and lighting systems with check-back function
- Connection of digital control units and devices of all kinds
- S-PVC jacket for mobile outdoor applications
Article number | 542-0051 |
---|---|
Name | Binary 422 TP DMX512 |
EAN | 4049371002424 |
Properties | Digital 110 Ω AES / EBU |
Properties | OFC oxygen free copper |
Properties | Analog |
Properties | In-ground / burial |
Application area | ELA 100 V |
Application area | Stage / live |
Application area | Installation |
Application area | Studio / Broadcast |
Application area | Mobile outdoor / indoor |
Application | DMX |
Colour | black |
Colour detailed | black |
Signal transmission | symmetrical |
Construction | [2(2LI2YS0,22mm²)(ST)]CY |
Jacket material | S-PVC |
Jacket Ø [mm] | 8,00 |
Number of Channels (AES/EBU, DMX) | 1 |
Inner conductor (AES/EBU, DMX) | 4 |
Inner conductor (AES/EBU, DMX) [mm²] | 0,22 |
Inner conductor Ø (AES/EBU, DMX) [mm] | 0,53 |
AWG (AES/EBU, DMX) | 24 |
Shielding | Copper braiding tin-plated + 2 x AL / PT foil |
Shielding factor [%] | 100 |
Copper strands (AES/EBU, DMX) | 7 |
Copper strand Ø (AES/EBU, DMX) [mm] | 0,20 |
Conductor insulation material | Foam / Skin-PE |
Conductor insulation Ø [mm] | 1,55 |
Weight per 1 m [g] | 76 |
UV-resistant | yes |
Fire load per m [kWh] | 0,25 |
Style variant | round |
Packing | 100 m spool |
Temperature min. [°C] | -25 |
Temperature max. [°C] | 70 |
Width [mm] | 8 |
[mm] | 8 |
Capac. cond./cond. per 1 m (AES/EBU, DMX) [pF] | 45 |
Capacity wire/wire at 1 ft. (AES/EBU, DMX) [pF] | 13,716 |
Capac. cond./shield. per 1 m (AES/EBU, DMX) [pF] | 110 |
Capacity wire/electic screen at 1 ft. (AES/EBU, DMX) [pF] | 33,528 |
Impedance [Ω] | 110 |
Insulation resist. per 1 km [GΩ] | 0,1 |
Insulation resist. per 1000 feet [GΩ] | 0,0305 |
Insulation resist. per 1 km (AES/EBU, DMX) [GΩ] | 0,1 |
Insulation resist. per 1000 feet (AES/EBU, DMX) [GΩ] | 0,0305 |
Conductor resistance per 1 km [Ω] | 87 |
Conductor resistance per 1000 ft. [Ω] | 26,5176 |
Shield. resistance per 1 km [Ω] | 15 |
Shield. resistance per 1000 ft. [Ω] | 4,572 |
BPVo-Euroclass | Fca |