• Product 125 of 130
100-0616

Telecommunication cable Logicable LG; PVC, flame-retardant; grey | 2 x 0,60 mm x number of pairs

  • Product 125 of 130
100-0616

Telecommunication cable Logicable LG; PVC, flame-retardant; grey | 2 x 0,60 mm x number of pairs

2,78 €*

Good news...

or less positive ones can be transmitted with our Logicable LG telecommunication cable. Ideal for voice units, extension lines or control and measurement data signals. May be installed indoor, in dry or wet zones or outdoor on shady outside walls. The wires are color-coded in accordance with VDE 0815 and stranded in pairs, while the pairs are stranded in layers. Optimum protection against electrical interference fields is provided by an AL/PT overall foil screen. In terms of thickness and material the robust, flame-retardant PVC outer jacket complies with the DIN VDE 0207/5 and VDE 0815/Tab.19 PVC standards. It is self-extinguishing pursuant to VDE 0482-332-1-2/IEC 60332-1. The Logicable LG complies with the EC low voltage directive EWG93/68/ or EWG73/23. Not suitable for power current and underground installation.

Advantages:

  • Available from 2- to 100-pair versions
  • Complies with the VDE 0815, VDE 0482-332-1-2/IEC 60332-1 standards and other requirments

Application:

  • Telecommunication installation cable for branch and desktop stations or for control and measurement data signals
  • for indoor and outdoor fixed installations
Article number 100-0616
Name Logicable LG
Properties OFC oxygen free copper
Properties Analog
Application area ELA 100 V
Application area Installation
Application Telecommunication cable
Colour grey
Colour detailed grey
Signal transmission symmetrical
Jacket material PVC, flame-retardant
Jacket material (audio) PVC, flame-retardant and self-extinguishing according to VDE 0482-332-1-2 / IEC 60332-1
Inner conductor (audio) 2
Inner conductor (audio) [mm²] 0,28
Inner conductor Ø (audio) [mm] 0,60
AWG (audio) 23
Shielding AL / PT foil + filler strand
Shielding factor [%] 100
Conductor insulation material PVC accord. to VDE 0207/4
Style variant round
Packing bulk stock
Temperature min. [°C] -30
Temperature max. [°C] 70
Capac. cond./cond. per 1 m (audio) [pF] 100
Capacity wire/wire at 1 ft. (audio) [pF] 30,48
Capac. cond./shield. per 1 m (audio) [pF] 300
Capacity wire/electic screen at 1 ft. (audio) [pF] 91,44
Impedance [Ω] 105
Insulation resist. per 1 km [GΩ] 0,1
Insulation resist. per 1000 feet [GΩ] 0,0305
Insulation resist. per 1 km (audio) [GΩ] 0,1
Insulation resist. per 1000 feet (audio) [GΩ] 0,0305
Test voltage [V] 800
Loop resistance per km [Ω] 130
Loop resistance per 1000 ft. [Ω] 39,624
BPVo-Euroclass Fca

Good news...

or less positive ones can be transmitted with our Logicable LG telecommunication cable. Ideal for voice units, extension lines or control and measurement data signals. May be installed indoor, in dry or wet zones or outdoor on shady outside walls. The wires are color-coded in accordance with VDE 0815 and stranded in pairs, while the pairs are stranded in layers. Optimum protection against electrical interference fields is provided by an AL/PT overall foil screen. In terms of thickness and material the robust, flame-retardant PVC outer jacket complies with the DIN VDE 0207/5 and VDE 0815/Tab.19 PVC standards. It is self-extinguishing pursuant to VDE 0482-332-1-2/IEC 60332-1. The Logicable LG complies with the EC low voltage directive EWG93/68/ or EWG73/23. Not suitable for power current and underground installation.

Advantages:

  • Available from 2- to 100-pair versions
  • Complies with the VDE 0815, VDE 0482-332-1-2/IEC 60332-1 standards and other requirments

Application:

  • Telecommunication installation cable for branch and desktop stations or for control and measurement data signals
  • for indoor and outdoor fixed installations
Article number 100-0616
Name Logicable LG
Properties OFC oxygen free copper
Properties Analog
Application area ELA 100 V
Application area Installation
Application Telecommunication cable
Colour grey
Colour detailed grey
Signal transmission symmetrical
Jacket material PVC, flame-retardant
Jacket material (audio) PVC, flame-retardant and self-extinguishing according to VDE 0482-332-1-2 / IEC 60332-1
Inner conductor (audio) 2
Inner conductor (audio) [mm²] 0,28
Inner conductor Ø (audio) [mm] 0,60
AWG (audio) 23
Shielding AL / PT foil + filler strand
Shielding factor [%] 100
Conductor insulation material PVC accord. to VDE 0207/4
Style variant round
Packing bulk stock
Temperature min. [°C] -30
Temperature max. [°C] 70
Capac. cond./cond. per 1 m (audio) [pF] 100
Capacity wire/wire at 1 ft. (audio) [pF] 30,48
Capac. cond./shield. per 1 m (audio) [pF] 300
Capacity wire/electic screen at 1 ft. (audio) [pF] 91,44
Impedance [Ω] 105
Insulation resist. per 1 km [GΩ] 0,1
Insulation resist. per 1000 feet [GΩ] 0,0305
Insulation resist. per 1 km (audio) [GΩ] 0,1
Insulation resist. per 1000 feet (audio) [GΩ] 0,0305
Test voltage [V] 800
Loop resistance per km [Ω] 130
Loop resistance per 1000 ft. [Ω] 39,624
BPVo-Euroclass Fca