• Product 10 of 47
500-0051-4

SC-Monolith 4; power: 3 x 1,50 mm²; DMX: 2 x 0,14 mm²; PVC Ø 13,20 mm; black

  • Product 10 of 47
500-0051-4

SC-Monolith 4; power: 3 x 1,50 mm²; DMX: 2 x 0,14 mm²; PVC Ø 13,20 mm; black

15,43 €*

When the lights begin to dance...

Advantages:

  • Parallel control for lighting boards through one cable via power line and DMX signal
  • Very flexible and enormously tread-resistant due to the round jacket made of cotton and viscose
  • Very good pairwise shielding of the DMX lines due to tinned helical copper mesh screen or copper braiding

Application:

  • Control line for DMX lighting consoles (wave impedance of 110 Ω)
  • Analogue + digital audio multipair with power supply
Name SC-Monolith 4
Properties Analog
Properties Digital 110 Ω AES / EBU
Properties OFC oxygen free copper
Application area Mobile outdoor / indoor
Application area Stage / live
Application area Installation
Application area Studio / Broadcast
Application DMX & Power
Colour black
Colour detailed black
Signal transmission symmetrical
Construction [(3LIY1,5mm²)Y+ 04(2LI2Y0,14mm²)DY]VLY
Construction (power) (3LIY1,5mm²)Y
Construction (AES/EBU, DMX) 04(2LI2Y0,14mm²)DY
Jacket material PVC
Jacket Ø [mm] 13,20
Jacket Ø (power) [mm] 6,20
Jacket Ø (AES/EBU, DMX) [mm] 3,00
Number of Channels (power) 1
Number of Channels (AES/EBU, DMX) 4
Inner conductor (power) 3
Inner conductor (AES/EBU, DMX) 2
Inner conductor (power) [mm²] 1,50
Inner conductor (AES/EBU, DMX) [mm²] 0,14
Inner conductor Ø (power) [mm] 1,38
Inner conductor Ø (AES/EBU, DMX) [mm] 0,42
AWG (power) 15
AWG (AES/EBU, DMX) 25
Shielding (AES/EBU, DMX) Copper spiral, tin-plated
Copper strands (power) 28
Copper strands (AES/EBU, DMX) 36
Copper strand Ø (power) [mm] 0,25
Copper strand Ø (AES/EBU, DMX) [mm] 0,07
Wire insulation material (power) PVC
Conductor insulation Ø [mm] 0,00
Conductor insulation Ø (power) [mm] 2,30
Conductor insulation Ø (AES/EBU, DMX) [mm] 1,15
Weight per 1 m [g] 350
UV-resistant yes
Fire load per m [kWh] 1,23
Style variant round
Shielding factor [%] 90
Packing bulk stock
Temperature min. [°C] -30
Temperature max. [°C] 70
Width [mm] 13,2
Height [mm] 13,2
Capac. cond./cond. per 1 m (AES/EBU, DMX) [pF] 52
Capacity wire/wire at 1 ft. (AES/EBU, DMX) [pF] 15,8496
Capac. cond./shield. per 1 m (AES/EBU, DMX) [pF] 89
Capacity wire/electic screen at 1 ft. (AES/EBU, DMX) [pF] 27,1272
Surge impedance (AES/EBU, DMX) [Ω] 110
Insulation resist. per 1 km [GΩ] 0
Insulation resist. per 1000 feet [GΩ] 0
Insulation resist. per 1 km (AES/EBU, DMX) [GΩ] 0,1
Insulation resist. per 1000 feet (AES/EBU, DMX) [GΩ] 0,0305
Conductor resistance per 1 km [Ω] 0
Conductor resistance per 1000 ft. [Ω] 0
Conductor resistance per 1 km (power) [Ω] 80
Conductor resistance per 1000 ft. (power) [Ω] 24,384
Shield. resistance per 1 km [Ω] 0
Shield. resistance per 1000 ft. [Ω] 0
Operating voltage (power) [V] 0
EAN 4049371003803
Fca
SC-Monolith 4
DMX & Power

Advantages:
- Parallel control for lighting boards through one cable via power line and DMX signal
- Very flexible and enormously tread-resistant due to the round jacket made of cotton and viscose
- Very good pairwise shielding of the DMX lines due to tinned helical copper mesh screen or copper braiding

Application:
- Control line for DMX lighting consoles (wave impedance of 110 Ω)
- Analogue + digital audio multipair with power supply

Technical Data:
- Name: SC-Monolith 4
- Properties: OFC oxygen free copper
- Properties: Analog
- Properties: Digital 110 Ω AES / EBU
- Application area: Stage / live
- Application area: Studio / Broadcast
- Application area: Installation
- Application area: Mobile outdoor / indoor
- Application: DMX & Power
- Colour: black
- Colour detailed: black
- Signal transmission: symmetrical
- Jacket material: PVC
- Jacket Ø: 13,2 mm
- Jacket Ø (power): 6,2 mm
- Jacket Ø (AES/EBU, DMX): 3 mm
- Number of Channels (power): 1
- Number of Channels (AES/EBU, DMX): 4
- Inner conductor (power): 3
- Inner conductor (AES/EBU, DMX): 2
- Inner conductor (power): 1,5 mm²
- Inner conductor (AES/EBU, DMX): 0,14 mm²
- Inner conductor Ø (power): 1,38 mm
- Inner conductor Ø (AES/EBU, DMX): 0,42 mm
- AWG (power): 15
- AWG (AES/EBU, DMX): 25
- Shielding (AES/EBU, DMX): Copper spiral, tin-plated
- Copper strands (power): 28
- Copper strands (AES/EBU, DMX): 36
- Copper strand Ø (power): 0,25 mm
- Copper strand Ø (AES/EBU, DMX): 0,07 mm
- Wire insulation material (power): PVC
- Conductor insulation Ø (power): 2,3 mm
- Conductor insulation Ø (AES/EBU, DMX): 1,15 mm
- Weight per 1 m: 350 g
- UV-resistant: yes
- Fire load per m: 1,23 kWh
- Style variant: round
- Shielding factor: 90 %
- Packing: bulk stock
- Temperature min.: -30 °C
- Temperature max.: 70 °C
- Width: 13,2 mm
- Height: 13,2 mm
- Capac. cond./cond. per 1 m (AES/EBU, DMX): 52 pF
- Capac. cond./shield. per 1 m (AES/EBU, DMX): 89 pF
- Surge impedance (AES/EBU, DMX): 110 Ω
- Insulation resist. per 1 km (AES/EBU, DMX): 0,1 GΩ
- Conductor resistance per 1 km (power): 80 Ω
- : Fca

When the lights begin to dance...

Advantages:

  • Parallel control for lighting boards through one cable via power line and DMX signal
  • Very flexible and enormously tread-resistant due to the round jacket made of cotton and viscose
  • Very good pairwise shielding of the DMX lines due to tinned helical copper mesh screen or copper braiding

Application:

  • Control line for DMX lighting consoles (wave impedance of 110 Ω)
  • Analogue + digital audio multipair with power supply
Name SC-Monolith 4
Properties Analog
Properties Digital 110 Ω AES / EBU
Properties OFC oxygen free copper
Application area Mobile outdoor / indoor
Application area Stage / live
Application area Installation
Application area Studio / Broadcast
Application DMX & Power
Colour black
Colour detailed black
Signal transmission symmetrical
Construction [(3LIY1,5mm²)Y+ 04(2LI2Y0,14mm²)DY]VLY
Construction (power) (3LIY1,5mm²)Y
Construction (AES/EBU, DMX) 04(2LI2Y0,14mm²)DY
Jacket material PVC
Jacket Ø [mm] 13,20
Jacket Ø (power) [mm] 6,20
Jacket Ø (AES/EBU, DMX) [mm] 3,00
Number of Channels (power) 1
Number of Channels (AES/EBU, DMX) 4
Inner conductor (power) 3
Inner conductor (AES/EBU, DMX) 2
Inner conductor (power) [mm²] 1,50
Inner conductor (AES/EBU, DMX) [mm²] 0,14
Inner conductor Ø (power) [mm] 1,38
Inner conductor Ø (AES/EBU, DMX) [mm] 0,42
AWG (power) 15
AWG (AES/EBU, DMX) 25
Shielding (AES/EBU, DMX) Copper spiral, tin-plated
Copper strands (power) 28
Copper strands (AES/EBU, DMX) 36
Copper strand Ø (power) [mm] 0,25
Copper strand Ø (AES/EBU, DMX) [mm] 0,07
Wire insulation material (power) PVC
Conductor insulation Ø [mm] 0,00
Conductor insulation Ø (power) [mm] 2,30
Conductor insulation Ø (AES/EBU, DMX) [mm] 1,15
Weight per 1 m [g] 350
UV-resistant yes
Fire load per m [kWh] 1,23
Style variant round
Shielding factor [%] 90
Packing bulk stock
Temperature min. [°C] -30
Temperature max. [°C] 70
Width [mm] 13,2
Height [mm] 13,2
Capac. cond./cond. per 1 m (AES/EBU, DMX) [pF] 52
Capacity wire/wire at 1 ft. (AES/EBU, DMX) [pF] 15,8496
Capac. cond./shield. per 1 m (AES/EBU, DMX) [pF] 89
Capacity wire/electic screen at 1 ft. (AES/EBU, DMX) [pF] 27,1272
Surge impedance (AES/EBU, DMX) [Ω] 110
Insulation resist. per 1 km [GΩ] 0
Insulation resist. per 1000 feet [GΩ] 0
Insulation resist. per 1 km (AES/EBU, DMX) [GΩ] 0,1
Insulation resist. per 1000 feet (AES/EBU, DMX) [GΩ] 0,0305
Conductor resistance per 1 km [Ω] 0
Conductor resistance per 1000 ft. [Ω] 0
Conductor resistance per 1 km (power) [Ω] 80
Conductor resistance per 1000 ft. (power) [Ω] 24,384
Shield. resistance per 1 km [Ω] 0
Shield. resistance per 1000 ft. [Ω] 0
Operating voltage (power) [V] 0
EAN 4049371003803
Fca
SC-Monolith 4
DMX & Power

Advantages:
- Parallel control for lighting boards through one cable via power line and DMX signal
- Very flexible and enormously tread-resistant due to the round jacket made of cotton and viscose
- Very good pairwise shielding of the DMX lines due to tinned helical copper mesh screen or copper braiding

Application:
- Control line for DMX lighting consoles (wave impedance of 110 Ω)
- Analogue + digital audio multipair with power supply

Technical Data:
- Name: SC-Monolith 4
- Properties: OFC oxygen free copper
- Properties: Analog
- Properties: Digital 110 Ω AES / EBU
- Application area: Stage / live
- Application area: Studio / Broadcast
- Application area: Installation
- Application area: Mobile outdoor / indoor
- Application: DMX & Power
- Colour: black
- Colour detailed: black
- Signal transmission: symmetrical
- Jacket material: PVC
- Jacket Ø: 13,2 mm
- Jacket Ø (power): 6,2 mm
- Jacket Ø (AES/EBU, DMX): 3 mm
- Number of Channels (power): 1
- Number of Channels (AES/EBU, DMX): 4
- Inner conductor (power): 3
- Inner conductor (AES/EBU, DMX): 2
- Inner conductor (power): 1,5 mm²
- Inner conductor (AES/EBU, DMX): 0,14 mm²
- Inner conductor Ø (power): 1,38 mm
- Inner conductor Ø (AES/EBU, DMX): 0,42 mm
- AWG (power): 15
- AWG (AES/EBU, DMX): 25
- Shielding (AES/EBU, DMX): Copper spiral, tin-plated
- Copper strands (power): 28
- Copper strands (AES/EBU, DMX): 36
- Copper strand Ø (power): 0,25 mm
- Copper strand Ø (AES/EBU, DMX): 0,07 mm
- Wire insulation material (power): PVC
- Conductor insulation Ø (power): 2,3 mm
- Conductor insulation Ø (AES/EBU, DMX): 1,15 mm
- Weight per 1 m: 350 g
- UV-resistant: yes
- Fire load per m: 1,23 kWh
- Style variant: round
- Shielding factor: 90 %
- Packing: bulk stock
- Temperature min.: -30 °C
- Temperature max.: 70 °C
- Width: 13,2 mm
- Height: 13,2 mm
- Capac. cond./cond. per 1 m (AES/EBU, DMX): 52 pF
- Capac. cond./shield. per 1 m (AES/EBU, DMX): 89 pF
- Surge impedance (AES/EBU, DMX): 110 Ω
- Insulation resist. per 1 km (AES/EBU, DMX): 0,1 GΩ
- Conductor resistance per 1 km (power): 80 Ω
- : Fca
* incl. tax, plus shipping, without trade discount.