As old as Methuselah...
but as fit and good-looking as a young lad. The SC-Astral-LLX has a patented construction of carbon screens around solid wire and insulation plus a protective polyester foil underneath the PVC outer jacket. This prevents material fatigue and results in consistent damping values for years to come. Conventional SAT cables usually lose their good damping values during installation and assembly: the original round shape of the skin PE insulation becomes oval and the solid conductor loses its centre position even with only slight bendings. The two carbon screens of the SC-Astral-LLX stabilise the solid conductor and the skin PE insulation. Thus the cable maintains its round shape and electrical values, even after installation. This type of construction also enabled us to achieve super low damping values and a shielding factor of 120 dB! Hence the SC-Astral-LLX also meets the HDSDI standard and is suitable for long installation distances on large SAT receiving systems.
Advantages:
- Excellent transmission quality and damping values
- Consistent values even after installation for decades due to patented anti-aging construction
- For analog and digital applications, HD-SDI transmission quality
Application:
- High-end cable for broadband cable TV and digital SAT equipment
- For professional HDTV applications
Article number | 600-0960LLX |
---|---|
Name | SC-Astral-LLX |
EAN | 4049371001694 |
Properties | FRNC flame retardant |
Properties | SDI |
Properties | Halogen-free / LSZH |
Properties | Digital 75 Ω |
Properties | Analog |
Properties | OFC oxygen free copper |
Application area | Installation |
Application area | Studio / Broadcast |
Application | SAT-cable HD, 120dB, longlife |
Colour | white |
Colour detailed | white |
Construction | (1.13/5.0) 120 dB |
Jacket material | PVC |
Jacket Ø [mm] | 6,80 |
Number of Channels (video) | 1 |
Inner conductor (video) | 1 |
Inner conductor (video) [mm²] | 1,00 |
Inner conductor Ø (video) [mm] | 1,13 |
AWG (video) | 17 |
Shielding | Copper braiding tin-pl. + ALfoil + 2 x semiconductor |
Shielding factor [%] | 100 |
Copper strands (video) | 1 |
Copper strand Ø (video) [mm] | 1,13 |
Conductor insulation material | Foam / Skin-PE |
Conductor insulation Ø [mm] | 5,00 |
Weight per 1 m [g] | 70 |
Fire load per m [kWh] | 0,24 |
Style variant | round |
Packing | 100 m ring |
Packing | 500 m spool |
Temperature min. [°C] | -20 |
Temperature max. [°C] | 70 |
Width [mm] | 6,8 |
[mm] | 6,8 |
Damping at 100 MHz (100m & 20° C) [dB] | 5,5 |
Damping at 100 MHz (100 ft. & 20 °C / 68 °F) [dB] | 1,6764 |
Damping at 200 MHz (100m & 20° C) [dB] | 7,5 |
Damping at 200 MHz (100 ft. & 20 °C / 68 °F) [dB] | 2,286 |
Damping at 470 MHz (100m & 20° C) [dB] | 10,9 |
Damping at 470 MHz (100 ft. & 20 °C / 68 °F) [dB] | 3,3223 |
Damping at 862 MHz (100m & 20° C) [dB] | 15,5 |
Damping at 862 MHz (100 ft. & 20 °C / 68 °F) [dB] | 4,7244 |
Damping at 1000 MHz (100m & 20° C) [dB] | 17,5 |
Damping at 1000 MHz (100 ft. & 20 °C / 68 °F) [dB] | 5,334 |
Damping at 1485 MHz (100m & 20° C) [dB] | 21,9 |
Damping at 1485 MHz (100 ft. & 20 °C / 68 °F) [dB] | 6,6751 |
Damping at 1750 MHz (100m & 20° C) [dB] | 24,5 |
Damping at 1750 MHz (100 ft. & 20 °C / 68 °F) [dB] | 7,4676 |
Damping at 2150 MHz (100m & 20° C) [dB] | 27 |
Damping at 2150 MHz (100 ft. & 20 °C / 68 °F) [dB] | 8,2296 |
Damping at 3000 MHz (100m & 20° C) [dB] | 33 |
Damping at 3000 MHz (100 ft. & 20 °C / 68 °F) [dB] | 10,0584 |
Impedance [Ω] | 75 |
BPVo-Euroclass | Fca |
As old as Methuselah...
but as fit and good-looking as a young lad. The SC-Astral-LLX has a patented construction of carbon screens around solid wire and insulation plus a protective polyester foil underneath the PVC outer jacket. This prevents material fatigue and results in consistent damping values for years to come. Conventional SAT cables usually lose their good damping values during installation and assembly: the original round shape of the skin PE insulation becomes oval and the solid conductor loses its centre position even with only slight bendings. The two carbon screens of the SC-Astral-LLX stabilise the solid conductor and the skin PE insulation. Thus the cable maintains its round shape and electrical values, even after installation. This type of construction also enabled us to achieve super low damping values and a shielding factor of 120 dB! Hence the SC-Astral-LLX also meets the HDSDI standard and is suitable for long installation distances on large SAT receiving systems.
Advantages:
- Excellent transmission quality and damping values
- Consistent values even after installation for decades due to patented anti-aging construction
- For analog and digital applications, HD-SDI transmission quality
Application:
- High-end cable for broadband cable TV and digital SAT equipment
- For professional HDTV applications
Article number | 600-0960LLX |
---|---|
Name | SC-Astral-LLX |
EAN | 4049371001694 |
Properties | FRNC flame retardant |
Properties | SDI |
Properties | Halogen-free / LSZH |
Properties | Digital 75 Ω |
Properties | Analog |
Properties | OFC oxygen free copper |
Application area | Installation |
Application area | Studio / Broadcast |
Application | SAT-cable HD, 120dB, longlife |
Colour | white |
Colour detailed | white |
Construction | (1.13/5.0) 120 dB |
Jacket material | PVC |
Jacket Ø [mm] | 6,80 |
Number of Channels (video) | 1 |
Inner conductor (video) | 1 |
Inner conductor (video) [mm²] | 1,00 |
Inner conductor Ø (video) [mm] | 1,13 |
AWG (video) | 17 |
Shielding | Copper braiding tin-pl. + ALfoil + 2 x semiconductor |
Shielding factor [%] | 100 |
Copper strands (video) | 1 |
Copper strand Ø (video) [mm] | 1,13 |
Conductor insulation material | Foam / Skin-PE |
Conductor insulation Ø [mm] | 5,00 |
Weight per 1 m [g] | 70 |
Fire load per m [kWh] | 0,24 |
Style variant | round |
Packing | 100 m ring |
Packing | 500 m spool |
Temperature min. [°C] | -20 |
Temperature max. [°C] | 70 |
Width [mm] | 6,8 |
[mm] | 6,8 |
Damping at 100 MHz (100m & 20° C) [dB] | 5,5 |
Damping at 100 MHz (100 ft. & 20 °C / 68 °F) [dB] | 1,6764 |
Damping at 200 MHz (100m & 20° C) [dB] | 7,5 |
Damping at 200 MHz (100 ft. & 20 °C / 68 °F) [dB] | 2,286 |
Damping at 470 MHz (100m & 20° C) [dB] | 10,9 |
Damping at 470 MHz (100 ft. & 20 °C / 68 °F) [dB] | 3,3223 |
Damping at 862 MHz (100m & 20° C) [dB] | 15,5 |
Damping at 862 MHz (100 ft. & 20 °C / 68 °F) [dB] | 4,7244 |
Damping at 1000 MHz (100m & 20° C) [dB] | 17,5 |
Damping at 1000 MHz (100 ft. & 20 °C / 68 °F) [dB] | 5,334 |
Damping at 1485 MHz (100m & 20° C) [dB] | 21,9 |
Damping at 1485 MHz (100 ft. & 20 °C / 68 °F) [dB] | 6,6751 |
Damping at 1750 MHz (100m & 20° C) [dB] | 24,5 |
Damping at 1750 MHz (100 ft. & 20 °C / 68 °F) [dB] | 7,4676 |
Damping at 2150 MHz (100m & 20° C) [dB] | 27 |
Damping at 2150 MHz (100 ft. & 20 °C / 68 °F) [dB] | 8,2296 |
Damping at 3000 MHz (100m & 20° C) [dB] | 33 |
Damping at 3000 MHz (100 ft. & 20 °C / 68 °F) [dB] | 10,0584 |
Impedance [Ω] | 75 |
BPVo-Euroclass | Fca |