For curious people...
we have developed this cable. It contains a high-quality RG 59 video line and two additional insulated wires in one jacket. The SC-Classic Control is suitable for connecting surveillance monitors, where the 2 x 0.75 mm² are used as check back line. The cable has a robust PVC jacket which is ideal for outdoor installation.
Because of its design, this cable is oval and thus cannot be reeled.
Advantages:
- cable and control line in one cable
- Very durable and rugged due to high-quality PVC jacket
- Very easy handling and reasonably priced
Application:
- Connection of surveillance monitors
- Studio and fixed installations
1 | |
Article number | 600-0481-2075 |
Name | SC-Classic Control |
EAN | 4049371002448 |
Properties | OFC oxygen free copper |
Properties | Analog |
Properties | Digital 75 Ω |
Application area | Installation |
Application | RG59 & Control |
Colour | black |
Colour detailed | black |
Construction | [LI02YSC12Y0,60mm+2(2LI2Y0,75mm²)]Y |
Construction (video) | LI02YSC12Y0,60mm |
Construction (control) | 2(2LI2Y0,75mm²)Y |
Jacket material | PVC |
Jacket Ø [mm] | 10,50 |
Jacket Ø (video) [mm] | 0,00 |
Jacket Ø (control) [mm] | 0,00 |
Number of Channels (video) | 1 |
Number of Channels (control) | 2 |
Inner conductor (video) | 1 |
Inner conductor (video) [mm²] | 0,28 |
Inner conductors (control) [mm²] | 0,75 |
Inner conductor Ø (video) [mm] | 0,60 |
Inner conductor Ø (control) [mm] | 0,98 |
AWG (video) | 23 |
AWG (control) | 18 |
Shielding (video) | Copper braiding |
Shielding factor [%] | 90 |
Copper strands (video) | 1 |
Copper strands (control) | 0 |
Copper strand Ø (video) [mm] | 0,60 |
Wire insulation material (video) | PE |
Wire insulation material (control) | PVC |
Conductor insulation Ø (video) [mm] | 3,70 |
Weight per 1 m [g] | 122 |
UV-resistant | yes |
Fire load per m [kWh] | 0,3 |
Style variant | oval |
Packing | bulk stock |
Velocity factor | 0,66 |
Temperature min. [°C] | -20 |
Temperature max. [°C] | 70 |
Width [mm] | 10,5 |
Height [mm] | 8,5 |
Capacity wire/electic screen at 1m (video) [pF] | 67 |
Capacity wire/electic screen at 1 ft. (video) [pF] | 20,4216 |
Capacity wire/electic screen at 1m (control) [pF] | 67 |
Capacity wire/electic screen at 1 ft. (control) [pF] | 20,4216 |
Damping at 5 MHz (100m & 20° C) [dB] | 2,5 |
Damping at 5 MHz (100 ft. & 20 °C / 68 °F) [dB] | 0,762 |
Damping at 50 MHz (100m & 20° C) [dB] | 5,6 |
Damping at 50 MHz (100 ft. & 20 °C / 68 °F) [dB] | 1,7069 |
Damping at 100 MHz (100m & 20° C) [dB] | 7,7 |
Damping at 100 MHz (100 ft. & 20 °C / 68 °F) [dB] | 2,347 |
Damping at 200 MHz (100m & 20° C) [dB] | 11,8 |
Damping at 200 MHz (100 ft. & 20 °C / 68 °F) [dB] | 3,5966 |
Damping at 470 MHz (100m & 20° C) [dB] | 22,3 |
Damping at 470 MHz (100 ft. & 20 °C / 68 °F) [dB] | 6,797 |
Damping at 862 MHz (100m & 20° C) [dB] | 36 |
Damping at 862 MHz (100 ft. & 20 °C / 68 °F) [dB] | 10,9728 |
Damping at 1000 MHz (100m & 20° C) [dB] | 40,4 |
Damping at 1000 MHz (100 ft. & 20 °C / 68 °F) [dB] | 12,3139 |
Damping at 1485 MHz (100m & 20° C) [dB] | 54 |
Damping at 1485 MHz (100 ft. & 20 °C / 68 °F) [dB] | 16,4592 |
Damping at 1750 MHz (100m & 20° C) [dB] | 60,5 |
Damping at 1750 MHz (100 ft. & 20 °C / 68 °F) [dB] | 18,4404 |
Damping at 2150 MHz (100m & 20° C) [dB] | 68,6 |
Damping at 2150 MHz (100 ft. & 20 °C / 68 °F) [dB] | 20,9093 |
Impedance [Ω] | 75 |
Conductor resistance per 1 km [Ω] | 150 |
Conductor resistance per 1000 ft. [Ω] | 45,72 |
BPVo-Euroclass | Fca |
For curious people...
we have developed this cable. It contains a high-quality RG 59 video line and two additional insulated wires in one jacket. The SC-Classic Control is suitable for connecting surveillance monitors, where the 2 x 0.75 mm² are used as check back line. The cable has a robust PVC jacket which is ideal for outdoor installation.
Because of its design, this cable is oval and thus cannot be reeled.
Advantages:
- cable and control line in one cable
- Very durable and rugged due to high-quality PVC jacket
- Very easy handling and reasonably priced
Application:
- Connection of surveillance monitors
- Studio and fixed installations
1 | |
Article number | 600-0481-2075 |
Name | SC-Classic Control |
EAN | 4049371002448 |
Properties | OFC oxygen free copper |
Properties | Analog |
Properties | Digital 75 Ω |
Application area | Installation |
Application | RG59 & Control |
Colour | black |
Colour detailed | black |
Construction | [LI02YSC12Y0,60mm+2(2LI2Y0,75mm²)]Y |
Construction (video) | LI02YSC12Y0,60mm |
Construction (control) | 2(2LI2Y0,75mm²)Y |
Jacket material | PVC |
Jacket Ø [mm] | 10,50 |
Jacket Ø (video) [mm] | 0,00 |
Jacket Ø (control) [mm] | 0,00 |
Number of Channels (video) | 1 |
Number of Channels (control) | 2 |
Inner conductor (video) | 1 |
Inner conductor (video) [mm²] | 0,28 |
Inner conductors (control) [mm²] | 0,75 |
Inner conductor Ø (video) [mm] | 0,60 |
Inner conductor Ø (control) [mm] | 0,98 |
AWG (video) | 23 |
AWG (control) | 18 |
Shielding (video) | Copper braiding |
Shielding factor [%] | 90 |
Copper strands (video) | 1 |
Copper strands (control) | 0 |
Copper strand Ø (video) [mm] | 0,60 |
Wire insulation material (video) | PE |
Wire insulation material (control) | PVC |
Conductor insulation Ø (video) [mm] | 3,70 |
Weight per 1 m [g] | 122 |
UV-resistant | yes |
Fire load per m [kWh] | 0,3 |
Style variant | oval |
Packing | bulk stock |
Velocity factor | 0,66 |
Temperature min. [°C] | -20 |
Temperature max. [°C] | 70 |
Width [mm] | 10,5 |
Height [mm] | 8,5 |
Capacity wire/electic screen at 1m (video) [pF] | 67 |
Capacity wire/electic screen at 1 ft. (video) [pF] | 20,4216 |
Capacity wire/electic screen at 1m (control) [pF] | 67 |
Capacity wire/electic screen at 1 ft. (control) [pF] | 20,4216 |
Damping at 5 MHz (100m & 20° C) [dB] | 2,5 |
Damping at 5 MHz (100 ft. & 20 °C / 68 °F) [dB] | 0,762 |
Damping at 50 MHz (100m & 20° C) [dB] | 5,6 |
Damping at 50 MHz (100 ft. & 20 °C / 68 °F) [dB] | 1,7069 |
Damping at 100 MHz (100m & 20° C) [dB] | 7,7 |
Damping at 100 MHz (100 ft. & 20 °C / 68 °F) [dB] | 2,347 |
Damping at 200 MHz (100m & 20° C) [dB] | 11,8 |
Damping at 200 MHz (100 ft. & 20 °C / 68 °F) [dB] | 3,5966 |
Damping at 470 MHz (100m & 20° C) [dB] | 22,3 |
Damping at 470 MHz (100 ft. & 20 °C / 68 °F) [dB] | 6,797 |
Damping at 862 MHz (100m & 20° C) [dB] | 36 |
Damping at 862 MHz (100 ft. & 20 °C / 68 °F) [dB] | 10,9728 |
Damping at 1000 MHz (100m & 20° C) [dB] | 40,4 |
Damping at 1000 MHz (100 ft. & 20 °C / 68 °F) [dB] | 12,3139 |
Damping at 1485 MHz (100m & 20° C) [dB] | 54 |
Damping at 1485 MHz (100 ft. & 20 °C / 68 °F) [dB] | 16,4592 |
Damping at 1750 MHz (100m & 20° C) [dB] | 60,5 |
Damping at 1750 MHz (100 ft. & 20 °C / 68 °F) [dB] | 18,4404 |
Damping at 2150 MHz (100m & 20° C) [dB] | 68,6 |
Damping at 2150 MHz (100 ft. & 20 °C / 68 °F) [dB] | 20,9093 |
Impedance [Ω] | 75 |
Conductor resistance per 1 km [Ω] | 150 |
Conductor resistance per 1000 ft. [Ω] | 45,72 |
BPVo-Euroclass | Fca |